Παρασκευή 7 Απριλίου 2017

A forensic analysis of a fatal fire in an indoor shooting range using coupled fire and evacuation modelling tools

Publication date: Available online 6 April 2017
Source:Fire Safety Journal
Author(s): Zhaozhi Wang, Fuchen Jia, Edwin Richard Galea, Jun-Ho Choi
Coupled fire and evacuation computer simulations are used to numerically reconstruct a fatal fire that occurred in an indoor shooting range in Korea in 2009. Of the 16 occupants, 15 were killed and one survived. The analysis demonstrates that this approach can accurately reproduce the outcome of this fire. The approach is then used to forensically analyse the incident to identify factors significantly contributing to the high loss of life. In particular, occupant response times and flame spread rate over the polyurethane foam (PUF) cladded walls are investigated. The results suggest that it is unlikely that anyone could have survived if response times were greater than 5s. Furthermore, it is suggested that fatalities couldn't have been avoided even if response times were zero. It is also demonstrated that gunpowder residue on the PUF walls is the critical factor in producing the high loss of life. The average number of fatalities could be reduced from 14.9 in the reconstruction case to 0.1 if the walls are completely free of gunpowder residue. However, to completely eliminate fire related casualties, it is necessary to use a PUF wall cladding material with low flame spread rates together with an effective gunpowder cleaning system.



http://ift.tt/2oMeuba

Δεν υπάρχουν σχόλια:

Δημοσίευση σχολίου