Publication date: Available online 29 April 2017
Source:Fire Safety Journal
Author(s): Shota Takeuchi, Takayuki Aoki, Futoshi Tanaka, Khalid A.M. Moinuddin
In this study, fire experiments using a 1:20 model-scale tunnel were conducted to investigate the performance of natural ventilation in an underground road tunnel with six vertical shafts. The experimental parameters were the heat release rate of a fire source and the height of the shafts, and nine experiments were conducted in total. Furthermore, simple models were developed for predicting the temperature distribution of the smoke flowing under the tunnel ceiling. The following results were obtained: (1) In the experiments, the form of the smoke exhausted from the shaft became plug-holing when the shaft height was 1.0Ht, and became boundary layer separation when the height was 0.24Ht. (2) The average efficiency of heat exhaust was 0.16 when the form was plug-holing, and was 0.12 when the form was boundary layer separation. (3) When the form was plug-holing, the ratio of entrainment of fresh air became almost constant regardless of Ri. On the other hand, when the form was boundary layer separation, the ratio of entrainment of fresh air was smaller than that under the condition of plug-holing. (4) The temperature distribution under the tunnel ceiling predicted by the models agreed with that measured by the fire experiments in all cases.